Fire performance of cold, warm and hybrid LSF wall panels using numerical studies

Show simple item record

dc.contributor.author Perera, D.
dc.contributor.author Poologanathan, K.
dc.contributor.author Nanayakkara, S.M.A.
dc.contributor.author Konthesingha, K.M.C.
dc.date.accessioned 2022-08-29T10:42:00Z
dc.date.available 2022-08-29T10:42:00Z
dc.date.issued 2020
dc.identifier.citation Perera, D., et al. (2020). Perera, D.Fire performance of cold, warm and hybrid LSF wall panels using numerical studies. Thin-Walled Structures 157 (2020) 107109 en_US
dc.identifier.uri http://dr.lib.sjp.ac.lk/handle/123456789/11827
dc.description.abstract Robust and pre-fabrication construction techniques are the cutting edge practice in the building industry. Coldframe, warm-frame and hybrid-frame are three common Light-gauge Steel Frame (LSF) wall constructions applied for better energy performance. Still, the applications of the aforementioned wall configurations are restricted due to limited fire safety studies. This paper presents the fire performance investigations and results of cold-frame, warm-frame, and hybrid-frame LSF walls together with three novel configurations maintaining the same material quantities. Successfully validated 3D heat transfer finite element models were extended to six wall configurations. Time variant temperature profiles from Finite Element Analyses were evaluated against the established Load Ratio (LR)-Hot-Flange (HF) temperature curve to determine the structural fire resistance. Modified warm-frame construction showed the best performance where the Fire Resistance Level (FRL) is approximately twice that of conventional LSF wall configurations. Hence, the novel LSF wall configurations obtained by shifting the insulation material toward the fireside of the wall make efficient fire-resistant wall solutions and the new designs are proposed to be incorporated in modular constructions for enhanced fire performance. en_US
dc.language.iso en en_US
dc.publisher Elsevier en_US
dc.subject Fire performance Cold-frame Warm-frame Hybrid-frame LSF Wall configurations Modular walls Standard fire FRL en_US
dc.title Fire performance of cold, warm and hybrid LSF wall panels using numerical studies en_US