DSpace Repository

Accurate determination of organic CO D of wastewater treated by the Fenton Process in latex glove manufacturing industry

Show simple item record

dc.contributor.author Gunathilake, S.J.K.M.R.S.
dc.contributor.author Prashantha, M.A.B.
dc.contributor.author Cooray, P.L.A.T.
dc.date.accessioned 2017-10-26T04:00:21Z
dc.date.available 2017-10-26T04:00:21Z
dc.date.issued 2016
dc.identifier.citation Gunathilake, S.J.K.M.R.S., Prashantha, M.A.B., Cooray, P.L.A.T. (2016). "Accurate determination of organic CO D of wastewater treated by the Fenton Process in latex glove manufacturing industry", Proceedings of the Wayamba University International Conference, Sri Lanka, 19-20 August 2016, p. 243 en_US, si_LK
dc.identifier.uri http://dr.lib.sjp.ac.lk/handle/123456789/6151
dc.description.abstract Attached en_US, si_LK
dc.description.abstract Fenton reaction generates reactive hydroxyl radicals by the reaction between H 2O 2 and iron (Fe2+/Fe3+) is sometimes used in glove manufacturing industries to oxidize organic compounds in wastewater. Chemical oxygen demand (C O D ) is an important parameter used to assess the quality of raw and treated wastewater. The existing dichromate reflux method for organic C O D determination assumes that dichromate is only reacting with the organic compounds in the sample; however, the assumption is not valid for wastewater treated by the Fenton reagent because of the presence of residual amounts of H 2O 2 and Fe2+ which also react with dichromate. Hence the existing method was modified to improve its accuracy by eliminating these interferences. The Fenton reagent used here has 1400 mgL'1 of H2O 2 and 150 m gL1 of Fe2+ respectively. The simulated wastewater sample was prepared using ethanol, acetic acid and isopropyl alcohol. The Fenton reaction was initiated by mixing 100.0 mL of wastewater with 1.0 mL of the reagent. The final pH of the mixture was approximately 2.5. Sample aliquots (10.0 mL) were withdrawn from the mixture on hourly basis for 5 hours and determined its C O D value using the existing dichromate method. In addition, the residual concentrations of H2O 2 and Fe2+ in the sample aliquot were also determined by iodometric titration and 1,10- phenanthroline colorimetric method respectively. The theoretical equivalents of oxygen required for oxidizing H2O 2 and Fe2+ by dichromate were calculated from stoichiometric redox reactions between Fe2+, H2O 2 and dichromate. The oxygen equivalents calculated from the previous step were subtracted from the C O D values determined by the existing dichromate method to eliminate the interference caused by them. This correction improved the accuracy of the organic C O D values. According to the experimental data, C O D values determined by the existing method were always 20 % to 30 % greater than the corrected C O D value. It can be concluded that for the determination of organic C O D by the existing dichromate method overestimate the C O D value if reducible non-organic compounds are present in the sample and therefore, a correction is required to eliminate the interferences caused by the reducible non-organic compounds.
dc.language.iso en_US en_US, si_LK
dc.publisher Proceedings of the Wayamba University International Conference, Sri Lanka, 19-20 August 2016 en_US, si_LK
dc.subject COD en_US, si_LK
dc.subject Fenton en_US, si_LK
dc.subject Wastewater en_US, si_LK
dc.title Accurate determination of organic CO D of wastewater treated by the Fenton Process in latex glove manufacturing industry en_US, si_LK
dc.type Article en_US, si_LK